CLIMAmur Clay Block Range
Check out just some of the CLIMAmur Clay Block Construction System available.
For more information, pricing or to request samples, please CONTACT US.
CLIMAmur 42 Clay Block Construction System
Self-insulating clay brick 42 cm thick, filled with rock wool. For walls with integrated thermal insulation.
Installation principle: Rolled Masonry ® or Dryfix® Masonry.
Areas of use: for individual homes, collective dwellings and commercial buildings.
You can download the POROTHERM CLIMAmur 42 Technical Information HERE
Format (L x W x H in mm) | 248 x 425 x 249 |
The thickness of the wall | 42.5cm |
Number of blocks/m² | 16 |
Unit weight (kg) | 17.1 |
Weight wall masonry (kg) | 315 kg /m² |
Mechanical resistance | RC 60 |
Thermal performance | R = 5.44m²K /W
Up = 0.18 W/m² |
Fire protection | Fire classification A1 (Incombustible) |
Insulating masonry | type a |
CLIMAmur 36 Clay Block Construction System
Installation principle: Rolled Masonry® or Dryfix® Masonry.
Areas of use: For individual homes, collective dwellings and tertiary buildings.
You can download the POROTHERM CLIMAmur 36 Technical Information HERE.
Format (L x W x H in mm) | 248 x 365 x 249 |
The thickness of the wall | 36.5 cm |
Number of blocks/m² | 16 |
Unit weight (kg) | 14.7 |
Weight wall masonry (kg) | 280 kg /m² |
Mechanical resistance | RC 60 |
Thermal performance | R = 4.66m²K /W
Up = 0.21W/m² |
Fire protection | Fire classification A1 (Incombustible) |
Insulating masonry | type a |
CLIMAmur 30 Clay Block Construction System
Self-insulating clay brick 30 cm thick, filled with rock wool. For walls with integrated thermal insulation.
Installation principle: Rolled Masonry® or Dryfix® Masonry.
Areas of use: For individual homes, collective dwellings and tertiary buildings.
You can download the POROTHERM CLIMAmur 30 Technical Information HERE.
Format (L x W x H in mm) | 248 x 300 x 249 |
The thickness of the wall | 30 cm |
Number of blocks/m² | 16 |
Unit weight (kg) | 12.1 |
Weight wall masonry (kg) | 235 kg /m² |
Mechanical resistance | RC 60 |
Thermal performance | R = 3.86m²K/W
Up = 0.25W/m² |
Fire protection | Fire classification A1 (Incombustible) |
Insulating masonry | type a |